Starting AHB Services
300017-A Rev. 00
2-11
Site Manager requires that you specify input and output addresses to configure the
BootP relay agent on the AHB router. The input IP address is the ATM
unnumbered interface on which the DHCP request packet is received. The ATM
unnumbered interface address appears in the BootP Relay Agent table. Its last four
digits are 0.0.0<circuit_number>, where circuit number is the unnumbered circuit
that you configured.
The output IP address is the address of the local IP interface to which the DHCP
packets are forwarded.
To create a BootP relay agent forwarding table, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
IP
. The IP menu opens.
3. Choose
BootP
. The BOOTP menu opens.
4. Choose
Relay Agent Interface Table
. The BOOTP Relay Agent Interface Table
window opens, displaying the IP
interfaces that you configured on the AHB
router (ATM PVCs, circuitless IP
interface, and so forth).
5. Click on
Forward I/F
. The BOOTP Relay Agent Forwarding
Table window opens.
6. Click on
Add
. The BOOTP Addresses window opens.
7. Add a BootP forwarding entry by setting
the following parameters:
• Input IP Address
• Output IP Address
Click on Help or see the parameter
descriptions on A-11.
8. Click on
OK
. The BOOTP Relay Agent Forwarding
Table window opens.
9. Click on
Done
. The BOOTP Relay Agent Interface Table
window opens.
10. Click on
Done
. You return to the Configuration Manager
window.