Avaya Bay Command Console Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
System-Oriented Show Commands
117383-B Rev. 00
C-3
Slot Number Slot on which the login session for the serial port is running.
Baud Rate Current baud rate setting for the serial port.
Data Bits Number of data bits in the serial port’s configuration.
Parity Serial port’s current parity setting.
Stop Bits Number of stop bits in the serial port’s configuration.
Modem Control Configuration of modem control, as follows:
Disabled
- Port is directly connected to a device, such as a
dummy terminal or a terminal server.
Enabled
- Port is attached to a modem and modem leads are
enabled.
Lines/Screen Number of lines the serial port displays before displaying the more
prompt.
More Enable Setting of the Technician Interface
more
feature: Enabled or
Disabled (according to the MIB record). The Technician Interface
more
command affects only the current login session, doesn’t
change the MIB, and therefore doesn’t affect the setting of this field.
Port Prompt Technician Interface prompt.
Login Retries Maximum number of login retries; relevant only if modem control is
enabled. This value determines the maximum number of failed login
attempts a system allows on the serial port. If the maximum occurs,
the system hangs up on the line, causing a modem connection to
lose carrier detect.
Login Timeout
(min.)
Number of minutes allowed between when the system displays the
login banner and a user enters a login ID; relevant only if modem
control is enabled. If this timeout occurs, the system hangs up on
the line.
Password Time Out Number of minutes allowed for a user to enter a password. If this
timeout period occurs, the system hangs up on the line.
Command Time
Out
Command line timeout value; relevant only if modem control is
enabled. If someone doesn’t enter a command in this number of
minutes, the system hangs up on the serial port.
User Abort Logout Switch to execute control (^C) to break out of the user autoscript.
When a user autoscript is in effect and this parameter is enabled,
you can break out of the script when logged in as User, not
Manager. Also, if this parameter is enabled and the script
terminates due to an error, the system automatically logs you out.
Initial Search Path List of file system volumes to be searched when you run a script
without a volume specifier or if an autoscript does not contain a
volume specifier. The environment variable PATH is set to this
string. The string format is as follows:
<vol>
:[;
<vol>
: ...]
Example: 2:;3:;4:;5:
Vista de pagina 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 119 120