Editing APPN Parameters
308963-14.00 Rev 00
3-37
Parameter: Adjacent Node Name
Default: None
Options: Any valid name with up to 17 characters in the format
<NETID>
.
<NAME>
;
NETID
is the unique network name with up to 8
characters followed by a period, and
NAME
is the control point name with
up to 8 characters
Function: Identifies the name of the network and the adjacent node name.
Instructions: Type to 8 characters for the network ID name, follow with a period, then
type a control point name with up to 8 characters. You must use uppercase
characters only and the first character must be non-numeric. Blank spaces
(leading, trailing, and embedded) are not allowed in the node name. For
example, APPNNODE.CPONE is a valid entry for the Adjacent Node
Name parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.4.1.6