Configuring APPN Services
3-4 114049 Rev. A
Parameter: APPN Enable/Disable
Default: Enable
Options: Enable
| Disable
Function: Globally enables or disables APPN on the router.
Disable -- Forces every APPN interface existing on the node into the
“down” (inoperative) state.
Enable -- Reinitializes every APPN interface existing on the node; each
interface maintains the most recent setting of its own Interface Enable/
Disable parameter.
Instructions: Select Disable to force every APPN interface existing on the node into the
“down” (inoperative) state.
Select Enable to globally reinitialize all APPN interfaces configured on
the node; each interface will maintain the most recent setting of its own
Interface Enable/Disable parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.1.2
Parameter: Local Node Name
Default: None
Options: Any valid name with up to 17 characters in the format
<NETID.CPNAME>; NETID is the global network name with up to 8
characters followed by a period, and CPNAME is the control point name
with up to 8 characters
Function: The Local Node Name parameter identifies the unique name of the
network and the Bay Networks router node name.
Instructions: Specify up to 8 characters for the network ID name; follow with a period;
then type a control point name with up to 8 characters. You must use
uppercase characters only and the first character must be non-numeric.
Blank spaces (leading, trailing, and embedded) are not allowed in the
node name. For example, NETWORKA.SYSTEMA is a valid entry for
the Local Node Name parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.1.4
Vista de pagina 67