Avaya BCM Management Guía de usuario Pagina 229

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 488
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 228
Chapter 2 Fault Management System 225
Business Communications Manager - Management User Guide
Event ID: 330 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
loss of frame. The module is in a no-new-calls state. DTCM = %1.
Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 330, Sev=P5, Cat=C
Event ID: 331 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
controlled slip overflow. The module is in a no-new-calls state. DTCM
= %1.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 331, Sev=P5, Cat=C
Event ID: 332 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
remote alarm indication. The module is in a no-new-calls state. DTCM
= %1. Intervention is required to find out why the Digital Trunk
Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 332, Sev=P5, Cat=C
Event ID: 333 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
loss of frame in timeslot 16. The module is in a no-new-calls state.
DTCM = %1. Intervention is required to find out why the Digital Trunk
Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Logs: MSC event 333, Sev=P5, Cat=C
Event ID: 334 Message: This event is generated when the short-term alarm threshold has been
surpassed in the Digital Trunk Interface module for the detection of
alarm indication signal in time slot 16. The module is in a no-new-calls
state. DTCM = %1. Intervention is required to find out why the Digital
Trunk Interface module is alarmed.
User action: Intervention is required to find out why the Digital Trunk Interface
module is alarmed.
Alarm severity: Minor
Trap-type: Warning
Voice software Return to table: Component ID (alarm)/eventSource (trap) summary
Vista de pagina 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 487 488

Comentarios a estos manuales

Sin comentarios