Avaya Using Technician Interface Scripts Manual de usuario Pagina 537

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 788
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 536
show rredund
2-485
base
Displays the base record information for router redundancy. The base record controls
router redundancy for the entire system. The table includes the following information:
State State of the protocol. States include the following:
Up
Down
Init (initializing) and bidding
Not Pres (enabled but not yet started)
Wait SOS Reply (waiting for a reply to an SOS PDU)
Wait Pri Gdby (waiting for a Primary Good-bye PDU
Rcvd Pri Gdby (received a Primary Good-bye PDU)
Wait New Pri (Waiting for a New Primary PDU)
Delay Bidding
Role Role of the router: Primary or Secondary.
Group ID Identification number of this router redundancy group.
Member ID Identification number of this member of the group.
Priority This router’s priority to become the primary router if the current
primary router fails. A high value indicates higher priority.
Hello Timer The configured time interval, in seconds, between sending Hello
protocol data units (PDUs).
Bid Duration The amount of time, in seconds, for the bidding period that
determines which router in the group becomes the primary router.
Timeout Counter The number of Hello timer periods when the secondary routers do
not receive a Hello PDU from the primary router before they begin
to choose a new primary router.
Primary cfg file The name of the primary configuration file the router uses when it
boots or reboots as the primary router.
Role Switch Delay This parameter is not currently used.