Sample Display – show ds1e1 transmit errors
DS1E1 Logical Line Transmit Errors:
-----------------------------------
Log Underflow Descriptor
Slot Conn Line Circuit Frames Errors
---- ---- ---- ------- ---------- ----------
2 1 1 Boston 1 0
2 1 2 Chicago 0 0
2 2 1 Seattle 1 0
3 entries in table.
Sample Display – show ds1e1 transmit errors circuit Boston
DS1E1 Logical Line Transmit Errors:
-----------------------------------
Log Underflow Descriptor
Slot Conn Line Circuit Frames Errors
---- ---- ---- ------- ---------- ----------
2 1 1 Boston 1 0
Found 1 match out of 3 entries in table.
Underflow Frames Number of retransmission underflow errors. These occur when the
device’s FIFO buffer empties before the device obtains the next
DMA request.
Descriptor Errors Internal device error.