4. Use Site Manager to make sure that IP is enabled and TFTP is created in
the AN/ANH/ARN configuration file.
Refer to “Verifying the BOOTP Server Setup” later in this appendix.
5. Use Technician Interface commands to verify or correct the status of the
synchronous, Ethernet, or Token Ring connectors used for network
booting.
Refer to Using Technician Interface Software for instructions. Following are
some examples of AN/ANH/ARN commands and their responses, as well as
some connector and interface settings you should consider:
• Enter the following command to display the router driver:
get wfLinkModules.15.0
On AN and ANH models, the response is
wfLinkModules.wfANLoad.0 = 2147483648
On ARNs, the response is
wfLinkModules.wfARNLoad.0 = 2147483648
The response indicates that the AN/ANH/ARN driver is configured to run
in Slot 1 (the only AN/ANH/ARN slot).
The decimal number
2147483648 represents Slot 1. If the setting is not
2147483648, enter one of the following commands to correct it:
set wfLinkModules.15.0 2147483648;commit (for AN/ANH models)
set wfLinkModules.25.0 2147483648;commit (for ARNs)