4-29
Parameter: Clear Alarm Threshold
Default: 2 seconds
Range: 2 to 10 seconds
Function: Specifies the clear time (in seconds) for performance failure conditions. If
the defect or anomaly clears when this time interval expires, MCE1
records a performance cleared condition and logs an event message.
Instructions: Set the timer value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.8
Parameter: International Bit
Default: Disable
Options: Enable | Disable
Function: Specifies if the international bit should be set in the E1 frame.
Instructions: Select Enable to set the international bit, or select Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.16