Configuring Dial Services
4-26
Parameter: Accept Loopback Request
Default: Enable
Options: Enable | Disable
Function: Enables and disables loop-up and loop-down code detection circuitry in
the MCT1 Link Module. If you enable this parameter, this interface
accepts and complies with requests to go into loopback mode from a far-
end device.
Instructions: Enable or disable local loopback.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.10
Parameter: Loopback Configuration
Default: No Loopback
Options: No Loopback | Payload Loopback | Line Loopback
Function: Forces the DS1 interface into loopback. The far-end or intermediate
equipment then performs diagnostics on the network between that
equipment and the DS1 interface. After testing, set this parameter to No
Loopback to return the interface to a normal operating mode.
No Loopback – Returns the interface to nonloopback operation.
Payload Loopback – The received signal at this interface is looped
through the device. Typically, the received signal is looped back for re-
transmission after it has passed through the device’s framing function.
Line Loopback – The received signal at this interface does not go through
the framing device but is looped back out.
Instructions: Select the loopback configuration option.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.4.1.10