Alarm Manager
NN40011-031 Issue 1.2 BCM Rls 6.0 11
Profiles can be set against the various alarm destination types, along the
following criteria:
Critical
Critical/Major
Critical/Major/Minor
All
None
The application of this facility would allow only Critical alarms to be sent to e-
mail destinations for example, or to stop sending alarms to the Alarm Set.
You can also test a selected alarm. This allows you to test whether the LED or
alarm displays/destinations are functioning as expected. Testing an alarm
generates an alarm in the system. Alarms generated using the Test Alarm
feature are identified in the Alarms table by the words "Test Event" in the
alarm Problem Description field.
Enabling or Disabling Selected Alarms for Each
Destination/Display
Use the following procedure to determine which alarms are sent to the various
destinations or displays, on a per alarm basis.
1. From the Administration tab open the General folder, and then click
the Alarm Settings link.