Starting ATM and ATM Router Redundancy
308612-14.00 Rev 00
2-3
For example, the following command adds ATM to the BN configuration on
slot 5, connector 1:
box# atm slot 5 connector 1
atm/5/1#
Enabling Signaling (LANE and Classical IP Service Records Only)
To enable signaling on an ATM interface, navigate to the ATM prompt and enter:
signaling
For example, the following command enables UNI V3.0 (default) signaling on
slot 5, connector 1:
atm/5/1# signaling
signaling/5/1#
Defining an ATM Service Record
Using the BCC, you can define PVC, classical IP, and LANE service records.
Defining PVC Service
To define a PVC service record, navigate to the ATM interface prompt and enter:
pvc-service
<service_name>
encapsulation
<encapsulation_type>
service_name
is a unique text string that you assign to the service record.
encapsulation_type
is the data encapsulation type that you want the PVC service
record to use.
For example, the following command defines a PVC service record with the name
“boston” on ATM slot 5, connector 1:
atm/5/1# pvc-service boston encapsulation llc-snap
pvc-service/boston#
Note:
You must add at least one PVC to a PVC service record. Go to “Adding
PVCs” on page 2-4 for instructions.