Customizing Signaling
308612-14.00 Rev 00
4-17
setup-tx-timer T303 4 1 to 24 Specifies the Setup Sent timer value (in seconds).
This timer begins when the circuit initiates a call/
connection request by sending a SETUP message
over the signaling VC.
The Setup Sent timer stops when the circuit
receives a CONNECT message (indicating
connection), a CALL PROCEEDING message
(indicating that the network received the SETUP
message), or a RELEASE COMPLETE message
(indicating the rejection of the SETUP message)
from the network.
If the circuit does not receive one of these
messages within the allotted time, it transmits the
SETUP message again. If the circuit still does not
receive a response, it clears the connection.
setup-ack-rx-timer T304 30 30 to 120 Specifies the Setup Acknowledgement timer value
(in seconds). This timer begins when the circuit
receives a SETUP ACK message after initiating a
call/connection request, and restarts when the
circuit sends an INFO message over the signaling
VC. .
The Setup Acknowledgement timer stops when the
circuit receives a CONNECT message (indicating
connection), a CALL PROCEEDING message
(indicating that the network received the SETUP
message), or an ALERT from the network.
If the circuit does not receive one of these
messages within the allotted time, it clears the
connection.
This timer can be used with UNI Version 4.0 and
later.
(continued)
Table 4-1. Signaling Timer Descriptions
(continued)
BCC
Name
Site
Manager
Name
Default
Value Range Description