Avaya Troubleshooting Routers Guía para resolver problemas Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 254
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Troubleshooting an Operational Problem
3-5
a. If the ASN is in a stack, make sure the SPX slot dial on the rear panel
of each ASN points to a different slot ID. Turn the selector in either
direction so that the arrow on the selector points to the ID you want
to use (F
igure 3-1). Make sure the configuration matches the slot dial
setting.
Figure 3-1. Verifying the Slot ID on an ASN
b.
If the SPEX
®
Net Module does not support hot-swap, make sure that
a terminator plug connects to any unused ports labeled SPEX IN and
SPEX OUT. Make sure the thumbscrews on the terminator plug are
tight.
If the ASNs are in a stack and they do not support hot-swap, you must
terminate the SPEX IN port of the first ASN and the SPEX OUT port of
the last ASN. Make sure that for the remaining ASNs in the stack, the
SPEX OUT port of one ASN connects to the SPEX IN of the next.
Note: The ASN cables are long enough to skip one ASN in the stack for
troubleshooting purposes.
2
4
3
1
FR
FC
3
4
IN
OUT
1
2
4
3
DCD
2
1
F
SPEX
34004
SYNC
34001
F
DCD
F
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 253 254

Comentarios a estos manuales

Sin comentarios