Avaya R5.0: Guía de configuración Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
BCM Rls 5.0 Configuration Guide For: MTS/Allstream SIP Trunking
2009-00002508 Page 12 of 20
2. Add a “Remote Gateway” by clicking on the “Add” button.
3. In the “Add Remote Gateway” dialog box that is displayed, configure the fields as follows:
Description: Enter the logical name for the trunk destination
Destination Digits: Enter digits that identify the remote system as the call destination.
VoIP Protocol: SIP
Domain: SIP Domain name of MTS/Allstream. This will be provided by MTS/Allstream.
IP Address: Provide the IP address of the SBC. This will be provided by MTS/Allstream.
Port: Provide the optional UDP port number to which the BCM will send SIP messages.
GW Type: Set this field to Other.
MCDN Protocol: Set to None.
QoS Monitor: Leave unchecked
Tx Threshold: Leave this field at its default value of 0.0
4. Click the OK button
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Comentarios a estos manuales

Sin comentarios