Editing ATM Service and Interface Parameters
8-17
ATM Virtual Channel Link Parameter Descriptions
Use the following descriptions when setting the parameters in the ATM Virtual
Channel Link Parameters window.
Parameter: VPI Number
Default: None
Range: 0 to 255
Function: Identifies the virtual path of the PVC. The VPI is part of the cell header.
The header can contain a maximum of 8 VPI bits for a UNI connection.
This bit range allows for path identifiers from 0 to 255.
Instructions: Enter a value from 0 to 255.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.3
Parameter: VCI Number
Default: None
Range: 32 to 65535
Function: Identifies the virtual channel of the PVC. The VCI is part of the cell
header. The header can contain a maximum of 16 VCI bits. This bit range
allows for path identifiers from 0 to 65535.
Instructions: Enter a value from 32 to 65535.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.5.1.4
Note: ATM does not allow duplicate VPI/VCI pairs on the same physical
interface (that is, on the same link module). However, duplicate VPI/VCI pairs
can exist on different physical interfaces (that is, on different link modules).
Note: Following the recommendation of the ATM Forum, virtual channel
identifiers from 0 to 31 are reserved for signaling and added functionality.