BayRS, BCC, and Site Manager Software Version 15.1.0.0 Fixed Anomalies
308681-15.1 Rev 00
13
Site Manager Software Version 15.1.0.0 Fixed Anomalies
Nortel Networks has fixed the following anomalies in Site Manager Software
Version 15.1.0.0.
==========================================================
CR Q00027334-01: IP Traffic Filters
When you delete a single IP traffic filter, the precedence is still displayed and you
receive the message
Invalid data entered for Filter Enable
.
CR Q00042557-01: Traffic Filters
When you use Site Manager to create a large inbound traffic filter, Site Manager
incorrectly calculates the rule size for the fragments. This causes the BCC
show config –all
script to terminate.
CR Q00044195-02: SWSERV
When configuring Dial backup or Bandwidth on demand circuit pools, Site
Manager incorrectly prompts you for a filename, which results in the error
message
No name has been specified (N1100)
. After this, you cannot
see the pools you just configured without exiting and re-entering the window.
CR Q00046055-01: MIBs
The wfIfInOctets and wfIfOutOctets counters do not increment when you disable
WCP on one or both ends of a Frame Relay circuit.
CR Q00046422-01: MCT1
When a logical line’s circuit name is longer than 17 characters, you cannot
configure a time slot for that circuit.
CR Q00047951-01: SNA
Site Manager hangs when editing SNA inbound or outbound protocol priority
filters.