160 Diagnostics and Utilities
Enterprise Edge Networking Operations Guide P0910464 Issue 01
14.17.40
14.17.41
Command failed. Error in setting action
for input/output filters
Reason: You were attempting to set the
action for input/output filters on the
interface. The operation failed because,
there were no input or output filters
defined for the interface.
Add an input or output filter before
setting the action
14.17.68 Command failed. Error is setting static
route. This problem is caused by a
mismatch in destination network address
in its subnet mask specified in the route.
Match them. Bitwise ’AND’ of
destination address and subnet mask
should be equal to the destination
address.
The routing protocol is changed and the
screen didn’t update.
Refresh the screen by clicking on ’View
Refresh’ menu item.
The routing protocol for the interface
shows up as ’RIP’. But no RIP
configuration parameters show up on the
screen
Set the routing protocol back to ’NONE’
and then set to ’RIP’ again. The RIP
configuration field would show up.
14.5.77 Invalid Data Value. Static default route is
not permitted in this version. Reason:
You were setting a static route that was a
default route for the system. In this
release of Enterprise Edge, setting
default routes as static routes is not
permitted. The default route is managed
by the ’Net Link Manager’ component
that accepts the address of next hop
router on the primary and then adds or
deletes (manages) the default route in the
system.
None