Using the syslog Facility
B-15
Parameter: Slot Lower Bound
Default: 0
Range: 0 to 14
Function: Along with the Slot Upper Bound parameter, this parameter specifies the
slot or range of slots on which you want to filter the log messages for this
entity. (In the case of ASN routers, this parameter specifies the module for
the particular slot since an ASN router is considered a slot.)
Instructions: To specify a range of slots, enter the lower number of the range in this
field. You then enter the upper number of the range in the Slot Upper
Bound field described next.
The values you enter for lower and upper bound are included in the range.
For example, if you specify a lower bound of 1 and an upper bound of 4,
syslog forwards all messages that occur on Slots 1 through 4 (inclusive).
The syslog facility ignores event messages that occur on all other slots.
To filter events for a specific slot, enter the slot number in this field. Be
sure to enter the same number in the Slot Upper Bound field. For
example, to forward only the log messages that occur on Slot 2, enter 2 in
this field and in the Slot Upper Bound field.
If you do not want to use this filter, accept the default, 0. Be sure to do the
same in the Slot Upper Bound field.