Avaya Managing Routers and BNX Platforms Manual de usuario Pagina 208

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 254
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 207
Managing Routers and BNX Platforms
8-6 114083 Rev. A
7. Enter the IP address that you want to ping. Then click on OK.
You then return to the Ping at Intervals window.
8. In the display area in the window, click on the IP address for which you
want to configure the ping request.
9. Enter values for the parameters in the Ping at Intervals window, as
described in the next section.
10. Click on Apply.
11. Click on Ping Start to begin pinging the IP address at the interval you
specified.
Site Manager stores the results of the ping requests in the Ping MIB tables.
12. Repeat Steps 8 through 11 to configure (and start) ping requests for
additional IP addresses.
To stop pinging an address, select the address in the Ping at Intervals window and
click on Ping Stop.
Specifying Values for Ping at Intervals Parameters
Use the information in this section to specify values for the parameters in the Ping
at Intervals window. For each parameter, this section provides information about
default settings, valid parameter options, the parameter function, instructions for
setting the parameter, and the Management Information Base (MIB) object ID.
The Technician Interface lets you modify parameters by issuing
set and commit
commands that specify the MIB object ID. This process is equivalent to
modifying parameters using Site Manager.
For more information about using the Technician Interface to access the MIB,
refer to Using Technician Interface Software.
Caution: The Technician Interface does not verify that the value you enter for
a parameter is valid. Entering an invalid value can corrupt your configuration.