DECT Deployment Kit 2 65
Press Menu
Scroll to System
Dial ***76#
Scroll to Site Survey
Press OK
The FE value for the PP is the number of detected Sync/ACRC errors
within the last 100 receiving frames, for example, 1 sec. For proper
deployment, the FE value must not exceed 4.
The FE value is for the FP is the number of received Q1/Q2 bit
information within the last 100 receiving frames, for example 1 sec. For
proper deployment, the FE value must not exceed 4.
An RSSI value of -80dBm ... -85dBm is used to indicate the cell
boundary.
Use the following procedure to subscribe a handset that has
de-subscribed in error.
a.
Long-press the button on the basestation to open the DECT
system.
b. On the handset, navigate to Menu > System > Subscription >
New.
c.
Enter the PARK number provided at the bottom of the basestation.
d.
Enter the authorization code (the last 4 digits of the serial number
located at the bottom of the basestation).