Using the Bay Command Console (BCC)
G-22
308659-14.00 Rev 00
Specifying the Interval Between Polling Cycles
Syslog polls the events log buffer on each slot to retrieve any new messages
logged since the previous polling attempt. Syslog determines this interval by the
value of its log-poll-timer parameter.
You can accept the default 5-second interval that Syslog waits to reinitiate a
polling cycle across all slots, or you can navigate to the
syslog
context and enter:
log-poll-timer
<seconds>
seconds
specifies the interval between polling cycles.
Example:
box#
syslog
syslog#
log-poll-timer 7
Identifying a UNIX System Facility
The value of the log-facility parameter of any configured host determines which
UNIX system facility (local0 through local7) receives Syslog messages from the
device. You can accept the default setting (local7), or you can navigate to the
context of the desired
log-host
object and enter:
log-facility
<system_facility>
system_facility
is one of the following:
local0
local1
local2
local3
local4
local5
local6
local7
Example:
box#
syslog
syslog#
log-host/192.168.3.4
log-host/192.168.3.4#
log-facility local4