Using the Bay Command Console (BCC)
G-14
308659-14.00 Rev 00
You can create an entity filter to capture only event messages that have the severity
levels you specify. To create this type of filter:
• Specify a filter name.
• Specify an entity name.
• Set the event-lower-bound parameter to 0.
• Set the event-upper-bound parameter to 255 (the wildcard event number).
• Set the severity-mask parameter to one or more of the following: fault,
warning, info, trace, debug.
For example, creating an entity filter for FTP with a message severity-mask value
of
{warning fault info}, captures only FTP event messages with a severity level of
warning, fault, or information.
To set the severity levels for capturing and forwarding event messages to a remote
host, navigate to the appropriate filter context and enter:
severity-mask {all
|
none
|
<
level
>...}
all
specifies all severity levels.
none specifies no severity levels.
level is one or more of the following: fault, warning, info, trace, debug.
Note:
Syslog checks the message severity mask only when you accept the
default event message number range of 0 to 255. This causes Syslog to ignore
event numbers as criteria for filtering messages.