Configuring MCT1
6-41
Parameter: Signal Level (dB)
Default: 0.0
Options: -15 dB
| -7.5 dB | 0.0 dB | 0.5 dB | 0.8 dB | 1.1 dB | 1.5 dB
Function: Specifies the T1 transmit power level in decibels (dB). The DS1 values of
-15 and -7.5 dB are long-haul; the carrier determines these values if
0.0 dB is not sufficient.
The DSX1 values of 0.0, 0.5, 0.8, 1.1, and 1.5 dB are short-haul and
correlate with cable length as follows:
Instructions: Specify the decibel level according to the length of the cable or as
determined by the carrier.
MIB Object ID: 1.3.6.1.4.1.18.3.4.8.2.1.15
Running the Tests
When you have set the test parameters, you can test the line.
To test the MCT1 line:
1. Start at the MCT1 Port Actions window (refer to Figure 6-20).
2. Click on the appropriate Send Command.
Refer to T
able 6-1 for a list of the commands and their functions.
3. Click on Apply.
0.0 dB 0 to 133 ft
0.5 dB 133 to 266 ft
0.8 dB 266 to 399 ft
1.1 dB 399 to 533 ft
1.5 dB 533 to 655 ft
Caution: Initiating line tests affects all logical lines associated with that port
for the duration of the testing.