BCM Technical Configuration Guide V1.1 May, 2006
_______________________________________________________________________________________________________________________
NORTEL External Distribution
7
MBM
• Install onto appropriate BUS & Activate
• Get Loop numbers
• Activate Loops
ISDN
DNs
• Select DNs
• Assign target line
•Configure OLI
Loops
• Configure as “s” interface
• Assign DNs
Routing
• Verify PRI pool correctly programmed
Target
Line
• Map incoming spill
Polycom
• Program DNs
• Disable H.323 & SIP
• Configure SPIDs
Figure 2: Configuration Flow
2.3 MBM
The objective of the following steps is to insert and activate the ISDN Basic Rate Interface (BRI) MBM into the
BCM.
Firstly, identify an available BUS, and set the dip switches accordingly; in this example, we are using BUS 06.
Once inserted, set the programming to “Trunk Module”.