BayRS, BCC, and Site Manager Software Version 15.0.0.0 Fixed Anomalies
4
308681-15.0 Rev 00
CR 125462-1: DLSw
In an unequal SAP connection, if a SABME is received before the XID, the
connection is never established.
CR 125873-2: Frame Relay
The router faults under a heavy traffic load over a frame relay access line.
CR 126410-1: Frame Relay
FTPs fail when the path between the router and the server is configured with
multilane frame relay using the random algorithm.
CR 127018-1: ATM
A tag violation fault occurs on a router configured with more than 100 PVCs
when ATM priority queuing is enabled.
CR 127613-1: DLSw
Configuring a DLSw protocol priority queue traffic filter causes the router to fault.
CR 128275-1: X.25
X.25 slots fault over time with “out of mapping” errors when establishing more
than 61,000 X.25 PDN connections.
CR 129054-1: AOT
When you use BayRS AOT with a polled AOT device, you may get a larger than
expected response delay, which can cause the device to time out.
CR 129066-1: ATM
Regardless of the number of ATM service records, there is only one instance of
ifEntry for the ATM interface.
CR 129601-2: Octal Sync
If an octal sync port receives bursts of errored frames from the network, the port
will eventually hang.