CR 97043-1: Technician Interface
If you make several dynamic changes on an AN or ASN router with a large
configuration (that is, hundreds of dial on demand [DoD] or frame relay
interfaces), the router will give an error when trying to save the configuration.
CR 102621-1: ASN2
Request to log a warning message if the router detects that a remote power supply
has become operational and the sfRASNRPSUPresent management information
base (MIB) is set to “not present.”
CR 107003-2: OSPF
With multicast traffic, area border routers incorrectly age out type 3 summaries
when the designated router is bounced or disabled.
CR 107270-3: Frame Relay
When WCP is enabled on a frame relay circuit, the ifEntry in and out octet counts
are not reported correctly for compressed and pre-compressed data.
CR 109269-1: SWSERV
An ARN configured with a V.34 modem always answers an incoming call on the
first ring, regardless of the setting of S register 0 (S0 is the setting for the number
of rings to receive prior to answering the call) for Hayes mode.
CR 109386-1: ATMLANE
When an LEC drops, virtual circuits are left in the table associated with the down
circuit. Since the LEC is down, no VPI/VCI circuits should be associated with it.
The LEC will not come up until the circuits (VPI/VPI) are manually deleted.
CR 109531-2: IP
The IP global parameter ArpBufLimit prevents ARP storms from hogging all
buffers on a slot. The default value for this MIB is set to 75%; this prevents an
out-of-buffer condition when an NMS pings non-existent devices on a net.
CR 110490-1: ATM
The router does not support sfAtmizerVcITxClipFrames, so the value should