Avaya Bogen Universal Paging Access Module Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
[9]
Specific Instructions
Trunk Port Connections - Loop Start
NOTE: Controls for VOX DELAY, PAGING TIME, MODE Switch S5 and AUX switches
S1, S2, S3, and S5 are not operable in this mode.
Procedure
1. Mount and ground the UPAM as described in the General Instructions (pages 7-8).
2. Set MODE switches S1 and S2 to OFF position for use with the 48-volt power
supply.
3. Set MODE switches S3 and S4 for Pre-announce or Confirmation tone (as desired).
Note:
One of these modes must be selected for UPAM to operate correctly.
4. Set AUX switch S4 to ON position (located on top edge of unit - see Figure 5 on
page 16).
5. Connect "Tip" of trunk port to T terminal on UPAM (see Figure 2).
6. Connect "Ring" of trunk port to R terminal on UPAM.
7. Connect PT and PR terminals on UPAM to the paging system, as shown in Section
3. Connect the N.O. and COM terminals to the control pair of the amplifier, if
required. Also, connect any background music source to the BGM IN jack on the
UPAM.
8. Connect power supply + and - terminals to the +24V/48V and -24V/48V terminals
on UPAM, respectively. Plug the power supply into a grounded 110V AC wall
outlet.
9. Call the system and adjust the volume of the page using the paging system's
amplifier volume control.
10. Hang up and adjust the background music level using the UPAM BGM VOL
control.
11. Call the system and adjust the volume of the pre-announce/confirmation tone, using
the UPAM TONE VOL control.
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 29 30

Comentarios a estos manuales

Sin comentarios