Avaya Bogen Universal Paging Access Module Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
Station Port/Centrex Connections (cont'd)
Inhibit Default Timer
Changing Default Timer Range
Ring Delay
An option is available to inhibit the default timer. Do not inhibit the timer if AUX
switches S4 and S5 are in the OFF position (outlined in Important Centrex Settings
on page 15) and the VOX DELAY timer has been disabled (MODE switch S5 is
OFF). This situation may cause the UPAM to remain off-hook indefinitely. Also, do
not inhibit both the default and VOX timers unless the station line has CPC
capability.
To inhibit the default timer, set AUX switch S2 in the ON position. (NOTE: The
VOX and CPC disconnect methods are still available when the default timer is
inhibited.)
To change the timing of the default timer, set AUX switch S 1 to the ON position
(make sure that AUX switch S2 is OFF). This switch position will change the
default time to approximately 25 seconds minimum to 2 minutes 30 seconds
maximum.
Setting AUX switch S3 in the OFF position increases the length of time it takes to
answer the ringing line. This allows time for a talk path to be established before the
UPAM answers, thereby ensuring that the pre-announce or confirmation tone will
be heard. Central office or Centrex lines, which may be slower than other switching
equipment, may require this change.
Table 1. AUX Switch Settings
AUX Switch Bank
Default Timer Enable
6 sec. - 35 sec.
25 sec. - 2.5 min.
Default Timer Disable
Ring Delay Enable
Ring Delay Disable
Page Port, Loop/Gnd. Start Operation
Std. Station Port Operations
Centrex/OSI Operation
OFF
S1. S2
S2
S3
S4, S5
ON
S1
S2
S3
S4
S4, S5
Figure 5. AUX Switch Bank Location (top edge of unit)
[16]