Installing Sync/ISDN BRI Net Modules in ASN Platforms
B-2 115370-A Rev. A
The power drawn from the host chassis combined with that required for any other
cards and accessories must be within the power rating of the host chassis.
You must install the net module so as not to impair the integrity of the network
protection from hazardous voltages used or generated internally by the host
chassis.
Clearances and Creepage Distances
The clearances and creepage distances (shown as X and Y, respectively, in
T
able B-2 and Figure B-1) must be maintained between the card and
The host chassis in which it is installed
Any adjacent cards installed in the host chassis
The exception to this rule is the edge connector, which is located in the host
chassis backplane, where no minimum distance applies.
The creepage distances apply to the normal office environment. When the local
environment within the host chassis is subject to conductive pollution or dry
nonconductive pollution that could become conductive due to condensation, the
creepage distances shown in parentheses in T
able B-2 will apply.
Table B-2. Net Module Clearances and Creepage Distances
Clearance (X) Creepage (Y)
Voltage used or generated by other parts
of the host or expansion card
2.0 mm 2.4 (3.8) mm Up to 50 V rms or V dc
2.6 mm 3.0 (4.8) mm Up to 125 V rms or V dc
4.0 mm 5.0 (8.0) mm Up to 250 V rms or V dc
4.0 mm 6.4 (10.0) mm Up to 300 V rms or V dc