Configuring Line Services
5-22 115391-A Rev. A
The BayStream software detects the loss of synchronization between KG84A
devices by monitoring the number of FCS errors and valid frames received. If the
BayStream software detects FCS errors, and does not receive a valid frame within
a time you specify, it requests resynchronization. The BayStream software also
requests resynchronization if it determines that the previous resynchronization
request did not complete before the time you specified.
You can also force a resynchronization of the local KG84A device by pressing its
RESYNC button. The BayStream software can detect this type of remote
resynchronization also, and can request a new resynchronization if one does not
complete in the configured time period.
Configure KG84A support on synchronous lines that connect to KG84A
cryptographic devices, using the following parameters in the Edit SYNC
Parameters window.
KG84A Cycle
KG84A Sync Loss Interval
KG84A Remote Resync Wait
KG84A Sync Pulse
KG84A Cycle
By default, the timer cycle’s length is 100 milliseconds. This cycle value is used
by the timers on the other KG84A devices on the network. This also becomes the
polling cycle for monitoring FCS errors.
You can set the KG84A timer cycle to 5, 10, 25, 50, 100, 200, or 500 milliseconds
on this interface.
Note: Be sure to also set the RTS Enable parameter to Enable.
Site Manager: KG84A Cycle parameter: page A-65