Operation
Tone Level - Tone level can be regulated by the front-panel screwdriver-adjustable TONE LEVEL control. Clockwise
rotation increases the level of the tone signal.
Pitch Control - A recessed, screwdriver-adjustable, PITCH control is located on the side-panel and is used to
adjust the frequency of the tone signal.The signal can be varied to suit the individual application requirement.
Figure 2 shows how the Multi-Tone Generator may be used for emergency alarm signalling in an unattended system.
Program input is interrupted by a continuous alarm tone when an external sensing and switching device (i.e., a bi-metal
sensor) momentarily closes the contact at the TRIGGER terminal (“START”).A second external momentary switch con-
nected to the RESET terminal (“STOP”) restores the circuit when the switch is momentarily closed.
EXTERNAL CONTACTS REOPEN.
TERMINALS (DOTTED LINE).