Event Messages (MCT1 through OSPF)
117349-A Rev. A 6-61
Entity Code/Event Code 11/78
Decimal Identifier 16780110
Severity: Warning
Message: <class><byte | word> Write: Failed [<address>]=<data> (src=<source_data>)
SR=<contents>
Meaning: NVFS failed to write to the memory card. The <class> is the type of the internal class
device; it indicates the driver function that failed. The <address> is the address of the
failure. The <data> is the data that is currently at that address. The <source_data> is the
data that NVFS failed to write to the memory card. The <contents> are the contents in the
status register.
Action: If file system problems persist, contact the Bay Networks Technical Solutions Center.
Entity Code/Event Code 11/79
Decimal Identifier 16780111
Severity: Warning
Message: <class><byte | word> Erase: Failed <address>
Meaning: NVFS failed to perform an erase operation on the memory card. The <class> is the type
of the internal class device; it indicates the driver function that failed. The <address> is
the address of the failure.
Action: If file system problems persist, contact the Bay Networks Technical Solutions Center.
Entity Code/Event Code 11/80
Decimal Identifier 16780112
Severity: Warning
Message: <class><byte | word> Erase: Failed <address>, SR=<contents>
Meaning: NVFS failed to perform an erase operation on the memory card. The <class> is the type
of the internal class device; it indicates the driver function that failed. The <address> is
the address of the failure. The <contents> are the contents in the status register.
Action: If file system problems persist, contact the Bay Networks Technical Solutions Center.