Configuring ATM Services
9-4 117374-A Rev. A
Setting Signaling Timers
You can set several signaling timers. Table 9-1 shows the timer defaults, ranges,
and descriptions.
Table 9-1. Signaling Timer Descriptions
Name Default Range Description
T303 4 1 to 24 Defines the Setup Sent timer value (in seconds). This timer
begins when the circuit initiates a call/connection request by
sending a SETUP message over the signaling VC.
The Setup Sent timer stops when the circuit receives either a
CONNECT message (indicating connection), CALL
PROCEEDING message (indicating that the network received
the SETUP message), or RELEASE COMPLETE message
(indicating the rejection of the SETUP message) from the
network.
If the circuit does not receive one of these messages within
the allotted time, it transmits the SETUP message again. If the
circuit still does not receive a response, it clears the
connection.
T308 30 1 to 180 Defines the Release Sent timer value (in seconds). This timer
begins when the circuit sends a RELEASE message to initiate
clearing of an SVC. Sending this RELEASE message places
the network in the release request state.
The Release Sent timer stops when the circuit receives from
the network either a RELEASE message (that is, both the
circuit and the network sent RELEASE messages at the same
time) or a RELEASE COMPLETE message.
If the timer expires before the circuit receives one of these
messages, the circuit transmits the RELEASE message
again. If the circuit still does not receive a response, the circuit
releases the call reference and begins a restart procedure.
(continued)