Configuring application settings 155
Using Web-Based Management for the Business Policy Switch 2000
Table 61 describes the items on the Port Configuration page.
2 In the upper-left hand corner, click on the unit number of the
switch to monitor.
3 Type information in the text boxes, or select from a list.
4 Click Submit.
Table 61 Port Configuration page items
Item Range Description
Port 1..28 The port number.
Port Name 1..16 Type character string to create a unique port name, for example,
Unit 1, Port 1.
Filter Tagged
Frames
(1) Yes
(2) No
Choose how to process filter tagged frames.
When a flag is set (Yes), the frames are discarded by the forwarding process.
When the flag is reset, the frames are processed normally.
The default setting is No (frames are not discarded).
Filter Untagged
Frames
(1) Yes
(2) No
Choose how to process filter untagged frames.
When a flag is set, the frames are discarded by the forwarding process.
The default setting is No (no frames discarded).
Filter Unregistered
Frames
(1) Yes
(2) No
Displays yes/no if a flag is set. If yes, unregistered frames are discarded by
the forwarding process. When the flag is reset, unregistered frames are
processed normally.
The default settings is No.
PVID 1..4094 Type the number of the VLAN ID to assign to untagged frames received on
this trunk port. For example, a port with a PVID of 3 assigns all untagged
frames received on this port to VLAN 3.
The default setting is 1.
Port Priority 0-7 Choose the level of priority for each port.
Link Type (1) Untagged Access
(2) Tagged Trunk
Choose the link type for each port.