Avaya BCM450 Manual de usuario

Busca en linea o descarga Manual de usuario para Ip Módulos Adicionales Avaya BCM450. Avaya BCM450 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Media Bay Modules

BCM450 Rls 6.0 Media Bay Modules Task Based Guide

Pagina 2 - All Rights Reserved

Media Bay Modules 10 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Global Analo

Pagina 3

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 11 Analog Station Media Bay Modules The Analog Station Media Bay Modules (ASM, ASM8, ASM8+,

Pagina 4 - Table of Contents

Media Bay Modules 12 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Global 4x16

Pagina 5

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 13 Up to 6 Norstar Expansion Modules can be connected via fibre cables to the FEM.

Pagina 6 - Flow Chart

Media Bay Modules 14 NN40011-003 Issue 1.2 BCM450 Rls 6.0  Main Unit:

Pagina 7 - Supported Media Bay Modules

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 15 An example installation with 6 MBM’s in the expansion unit is shown below. The Media B

Pagina 8

Media Bay Modules 16 NN40011-003 Issue 1.2 BCM450 Rls 6.0 4. Set the

Pagina 9

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 17 option of assigning Target Lines to the extensions on the MBM. Tick the Assign target li

Pagina 10

Media Bay Modules 18 NN40011-003 Issue 1.2 BCM450 Rls 6.0 9. If the BCM

Pagina 11

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 19 12. You will notice that the required Dip Switch configuration for each MBM is

Pagina 12

Media Bay Modules 2 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Copyright © 20

Pagina 13

Media Bay Modules 20 NN40011-003 Issue 1.2 BCM450 Rls 6.0 17. Click OK

Pagina 14 - Expansion Unit MBM Locations

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 21 The available Configured Device types for the Norstar Expansion Modules within Telepho

Pagina 15

Media Bay Modules 22 NN40011-003 Issue 1.2 BCM450 Rls 6.0 4. A further

Pagina 16

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 23 7. When the required Norstar Expansion Module type (and line card type for Norstar T

Pagina 17

Media Bay Modules 24 NN40011-003 Issue 1.2 BCM450 Rls 6.0  Norstar T

Pagina 18

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 25 Note: Do not install MBM’s whilst the BCM is powered up. 13. Switch to the Administr

Pagina 19

Media Bay Modules 26 NN40011-003 Issue 1.2 BCM450 Rls 6.0 16. An advisor

Pagina 20

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 27 Switch Configuration section of this guide for further information on configu

Pagina 21

Media Bay Modules 28 NN40011-003 Issue 1.2 BCM450 Rls 6.0 MBM’s Requirin

Pagina 22

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 29 GASM right hand side dipswitch settings (switch 1-3) GASM right hand side dipswitch s

Pagina 23

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 3 Downloading documents For the most current versions of documentation, see the Avaya Suppo

Pagina 24

Media Bay Modules 30 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Additional Inf

Pagina 25

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 31 3. Select the MBM to be removed or replaced, and click on the Deconfigure bu

Pagina 26

Media Bay Modules 32 NN40011-003 Issue 1.2 BCM450 Rls 6.0 5. All the co

Pagina 27

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 33 2. In the Configuration tab, open the Resources folder and click on Telephony

Pagina 28

Media Bay Modules 34 NN40011-003 Issue 1.2 BCM450 Rls 6.0 4. The State

Pagina 29

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 35 3. Select the MBM you want to further configure. The MBM specific settings ca

Pagina 30 - Additional Information

Media Bay Modules 36 NN40011-003 Issue 1.2 BCM450 Rls 6.0 6. When you h

Pagina 31

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 37 3. Secondary external: The DTM/BRI acts as a standby reference point. If there are e

Pagina 32 - Disabling/Enabling MBM’s

Media Bay Modules 38 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Checking Line

Pagina 33

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 39 1. In this example the system has a single PRI Digital Trunk Media Bay Module installed

Pagina 34

Media Bay Modules 4 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Table of Conte

Pagina 35

Media Bay Modules 40 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Attribute Val

Pagina 36 - Trunk Media Bay Modules

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 41 Attribute Value Module/line type 600-700 feet Set the distance between BCM and an ex

Pagina 37

Media Bay Modules 42 NN40011-003 Issue 1.2 BCM450 Rls 6.0 DPNSS Modules

Pagina 38 - DTM-PRI Modules

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 43 DPNSS Module-Specific Settings BRI Module 1. There are no module-specific setting

Pagina 39

Media Bay Modules 44 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Use the follow

Pagina 40

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 45 Attribute Value Description length of the loop can be a maximum of 1000 m (3230 ft)

Pagina 41 - DASS2 Modules

Media Bay Modules 46 NN40011-003 Issue 1.2 BCM450 Rls 6.0 CTM/GATM (4 an

Pagina 42 - DPNSS Modules

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 47 Station Media Bay Modules Types With station media bay modules (MBM) you can con

Pagina 43 - BRI Module

Media Bay Modules 48 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Attribute Val

Pagina 44

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 49 Attribute Value Module type Version This field indicates the version of firmware

Pagina 45

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 5 Media Bay Modules Overview Media Bay Modules (MBM’s) provide station (extension) and tru

Pagina 46 - Description

Media Bay Modules 50 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Media Bay Modu

Pagina 47

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 51 ADID4/8 Media Bay Module Amphenol Wiring Use the table below if connecting analog trunks

Pagina 48

Media Bay Modules 52 NN40011-003 Issue 1.2 BCM450 Rls 6.0 GATM4/8 Media

Pagina 49 - Combination Modules

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 53 G4/8x16 Media Bay Module Amphenol Wiring The G4/8x16 MBM’s is a combination of the GATM4

Pagina 50 - Wire Colour

Media Bay Modules 54 NN40011-003 Issue 1.2 BCM450 Rls 6.0 There are 4 li

Pagina 51

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 55 DTM Ports The digital trunks are connected to the DTM via the RJ-48C jack. The pin o

Pagina 52

Media Bay Modules 56 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Avaya Document

Pagina 53

Media Bay Modules 6 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Flow Chart Use

Pagina 54 - BRI Ports

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 7 Supported Media Bay Modules The following Media Bay Modules are supported on the BCM450:

Pagina 55 - DTM Ports

Media Bay Modules 8 NN40011-003 Issue 1.2 BCM450 Rls 6.0 Basic Rate I

Pagina 56 - Avaya Documentation Links

Media Bay Modules NN40011-003 Issue 1.2 BCM450 Rls 6.0 9 Caller ID Trunk Media Bay Module There are two types of Caller ID trunk media bay modules