32 Converged small site (mixed-vendor environment): reference topology 1
a. Click Configuration > SLOT 0 – Radio A > Security.
b. Select the Enable check boxes for VAP0 and VAP1.
c. Click Submit.
4 To set the default VLAN ID on BAP120—802.11b/g radio
a. Click Configuration > SLOT 1 – Radio G > Radio Settings to
access the Default VLAN ID (1~4094) table.
b. Enter the following individual settings for the VLAN IDs:
i. VAP0—1
ii. VAP1—2
iii. VAP3—1
iv. VAP4—1
c. Click Submit.
5
To enable Guest Access SSID on BAP120 – 802.11b/g radio
a. Click Configuration > SLOT 1 – Radio G > Security.
b. Select the Enable check boxes for VAP0 and VAP1.
c. Click Submit.
6
To enable the VLAN on BAP120
a. Click System > VLAN to access the VLAN Configuration table.
b. For the VLAN Classification, select Enable.
c. Enter 1 as the Native VLAN ID.
d. Click Submit.
A confirmation dialog box appears, asking you to confirm
changes and informing you that you may lose connectivity to
the BAP120.
e. In the confirmation dialog box, click OK, and then wait for
approximately 30 seconds before you proceed.
7
Disconnect the BAP120 from the VLAN #3 port, and then connect it
to one of the VLAN 2 ports on the BES100/200. For this example,
use port 2.
—End—