Avaya Redundancy BCM Rls 6.0 Manual de usuario

Busca en linea o descarga Manual de usuario para Arrays de discos Avaya Redundancy BCM Rls 6.0. Avaya Redundancy BCM Rls 6.0 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
BCM Rls 6.0
Redundancy
Task Based Guide
Vista de pagina 0
1 2 3 4 5 6 ... 32 33

Indice de contenidos

Pagina 1 - Redundancy

BCM Rls 6.0 Redundancy Task Based Guide

Pagina 2 - All Rights Reserved

Redundancy 10 NN40011-048 Issue 1.2 BCM450 Rls 6.0 3. Grasp the fan connector at the plug and pull to undo the connection. 4. Next, remove a

Pagina 3

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 11 5. The fan is held in place with plastic (two piece) grommets. Simply pull the pin out of t

Pagina 4 - Table of Contents

Redundancy 12 NN40011-048 Issue 1.2 BCM450 Rls 6.0 1. First, grasp the connectors and gently pull to remove the two plugs that connect the power s

Pagina 5

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 13 3. Once disconnected, remove all associated retaining screws for the power supply at th

Pagina 6 - RAID Keycode

Redundancy 14 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Note: You may require a cutting tool to assist in breaking the connection struts of

Pagina 7 - Flowchart

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 15 Removing the Front Hard Drive Cover The final preparation task is to remove the Front Hard Drive

Pagina 8 - Installation

Redundancy 16 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Completed Pre-Preparation Check List Upon completion ensure that you have removed:  The curre

Pagina 9 - Removing the Fan

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 17 Installing the Redundancy & RAID Kit For the purpose of this guide, we will install the foll

Pagina 10

Redundancy 18 NN40011-048 Issue 1.2 BCM450 Rls 6.0 1. Starting with the first unit, ensure the fan label is the right way up (power

Pagina 11 - Removing the Power Supply

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 19 3. Rest the fan faceplate on top of the unit (ensure that the lip of the facepl

Pagina 12

Redundancy 2 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Copyright © 2010 Avaya Inc. All Rights Reserved. Notices While reasonable efforts have been made

Pagina 13

Redundancy 20 NN40011-048 Issue 1.2 BCM450 Rls 6.0 5. Perform the same procedure for the second fan. 6. Both units should now be fixed to th

Pagina 14

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 21 7. Secure the faceplate to the chassis with the fixing screws. 8. Finally, clip both powe

Pagina 15

Redundancy 22 NN40011-048 Issue 1.2 BCM450 Rls 6.0 9. Your secondary fan is now installed alongside the original unit. Installing the Redundant

Pagina 16

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 23 1. Begin by removing the PSU Status jumper on the Chassis Interface Card. 2.

Pagina 17

Redundancy 24 NN40011-048 Issue 1.2 BCM450 Rls 6.0 3. Now that the plate has been removed, you can position the power supply as shown.

Pagina 18

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 25 5. Tidy away the cables as necessary, separating the same four leads that will connec

Pagina 19

Redundancy 26 NN40011-048 Issue 1.2 BCM450 Rls 6.0 7. Next, reconnect the two leads that will power the MBM’s. 8. Once completed, your connec

Pagina 20

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 27 9. You can now reseat the BCM 450 access panel and secure with the retaining screws. 10. The

Pagina 21

Redundancy 28 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Installing the Secondary Hard Disk Drive Installing a secondary Hard Disk Drive (for RAID

Pagina 22

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 29 3. The secondary Hard Disk Drive is now installed. Replace the front Hard Drive cover and tight

Pagina 23

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 3 Downloading documents For the most current versions of documentation, see the Avaya Support. Web

Pagina 24

Redundancy 30 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Note: The Disk Mirroring option only becomes visible after RAID keycode entry. 2. If the Ad

Pagina 25

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 31 3. Click on the drop down list to change the status, and click OK. 4. Click OK to the secon

Pagina 26

Redundancy 32 NN40011-048 Issue 1.2 BCM450 Rls 6.0 LED States HDD-1 LED RAID LED HDD-2 LED Description Green Green Green - BCM completed booting,

Pagina 27

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 33 Avaya Documentation Links  Troubleshooting Guide  Installation – System  Maintenance

Pagina 28

Redundancy 4 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Table of Contents Redundancy ...

Pagina 29

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 5 Redundancy Overview This guide will cover the installation procedures required to instal

Pagina 30

Redundancy 6 NN40011-048 Issue 1.2 BCM450 Rls 6.0 RAID Keycode Note: If installing the RAID kit, ensure that the RAID Keycode is showing as act

Pagina 31

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 7 Flowchart This flowchart depicts the steps necessary to upgrade a BCM 450 with a redu

Pagina 32

Redundancy 8 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Preparing the BCM 450 for Redundancy Kit Installation Before installing a Redundancy kit, th

Pagina 33 - Avaya Documentation Links

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 9 Removing the Fan To install the secondary fan and cover plate, the existing components need to be

Comentarios a estos manuales